Text Size

S01: Member Design For Axial Stress

Ver. 3.0.10 2017/06/21
  • Display area of file name enlarged.
Ver. 3.0.09 2017/06/14
  • Support added for Canadian code CSA S16-14.
Ver. 3.0.08 2017/03/31
  • Option added to include preferred sections only.
Ver. 3.0.07 2016/12/05
  • SANS 10162-2005: The torsional length factor was not multiplied with actual length.
Ver. 3.0.06 2016/12/02
  • SANS 10162-2005: The tosional length factor was always taken as one.
Ver. 3.0.05 2016/07/28
  • Problem with saved views, fixed.
Ver. 3.0.04 2016/06/29
  • Tapered sections now recognized consistently.
Ver. 3.0.03 2016/04/06
  • Compatibility problem with large fonts, fixed.
Ver. 3.0.02 2016/01/06
  • Occasional range check error during start up, fixed.
Ver. 3.0.01 2015/12/09
  • Correction of licensing error introduced by maintenance release.
Ver. 3.0.00 2015/12/01
  • Major release.
  • Implemented new user interface library.
Ver. 2.6.05 2015/07/22
  • Error message when opening analysis result from Sumo Structural Modeller, fixed.
Ver. 2.6.04 2015/06/09
  • Added support for New Zealand steel design code NZS 3404 - 1997.
Ver. 2.6.03 2015/01/21
  • Support added for Canadian steel design code CSA S16-09.
  • Number of load cases supported increased to 1000.
Ver. 2.6.02 2013/10/16
  • Rare problem with reading frame output file fixed.
Ver. 2.6.01 2013/07/24
  • Last effective length factors stored (Windows registry).
Ver. 2.6.00 2012/12/05
  • Maintenance release.
Ver. 2.5.10 2012/10/30
  • Added support for Frame Analysis output files with extensions other than ".OUT".
Ver. 2.5.09 2012/09/14
  • Code selection dialog were not fully visible with large fonts selection.
Ver. 2.5.08 2012/09/05
  • Maximum number of load cases increased from 200 to 500.
Ver. 2.5.07 2012/04/23
  • Problem with occasional access violation error fixed.
Ver. 2.5.06 2012/04/04
  • Fixed compatibility issues with analyses performed with Sumo Structural Modeller.
Ver. 2.5.05 2012/02/24
  • Non-preferred sectiond were not analysed.
Ver. 2.5.04 2011/11/04
  • SANS 10162-2005: Effective web area of class 4 T-sections corrected.
Ver. 2.5.03 2011/05/26
  • Design link with Frame updated to support new six-digit node format.
Ver. 2.5.02 2011/01/14
  • Provision made for six-digit node numbers (up to 999999).
Ver. 2.5.01 2010/07/28
  • Problems with position of dialog boxes on dual monitor computers, fixed.
Ver. 2.5.00 2010/07/05
  • New Release.
Ver. 2.4.10 2009/12/02
  • IS:800 - 2007 code which have not been added yet, now disabled.
Ver. 2.4.09 2009/09/10
  • Saved views now imported from Frame input file.
Ver. 2.4.08 2009/06/17
  • Warping constant (Cw) values added for lipped channels.
Ver. 2.4.07 2009/04/28
  • Value of shear centre for channels sections corrected.
Ver. 2.4.06 2009/01/27
  • Recompiled for compatibility with quest user configurations.
Ver. 2.4.05 2008/09/09
  • Graphical display of Laterally unsupported elements, improved.
  • Frame input file name now added to calcsheet.
Ver. 2.4.04 2008/08/28
  • Maintenance release.
Ver. 2.4.03 2008/06/12
  • T-section cut from I or H profiles, can now be selected individually.
Ver. 2.4.02 2008/05/08
  • Separate working folders now stored for multiple prokon installations on one PC.
Ver. 2.4.01 2008/04/03
  • AISC - 1999 LRFD now supported.
Ver. 2.4.00 2008/03/25
  • Maintenance release.
Ver. 2.3.01 2008/02/20
  • Range check error when no Frame output file found, fixed.
Ver. 2.3.00 2007/11/16
  • Prokon Ver 2.3.00.
Ver. 2.2.16 2007/02/20
  • Detailed equations for calls 4 sections (SANS 10162 - 2005):.
  • The value shown for f1 had already been reduced for the effective section.
  • width. Final results were not affected.
Ver. 2.2.15 2007/01/19
  • Maximum number of nodes increased from 50000 to 100000.
  • Maximum number of elements increased from 20000 to 30000.
Ver. 2.2.14 2006/10/31
  • SABS 0162 - 84: Problem with design parameters fixed.
Ver. 2.2.13 2006/09/08
  • Critical axis added to output tables.
Ver. 2.2.12 2006/09/04
  • Result setting now saved with .S01 file.
Ver. 2.2.11 2006/07/14
  • AISC LRFD -1993 updated to AISC LRFD -1999.
Ver. 2.2.10 2006/06/01
  • Settings button no longer resets the yield stress (Fy).
Ver. 2.2.09 2006/05/24
  • Problem with reading section properties (caused by version 2.2.07), fixed.
Ver. 2.2.08 2006/05/16
  • Problem with reading section properties (caused by version 2.2.07), fixed.
Ver. 2.2.07 2006/05/12
  • Section names containing spaces now supported.
Ver. 2.2.06 2006/05/09
  • Interactive Input: Problem with changing profiles, fixed.
Ver. 2.2.05 2006/04/20
  • SANS 10162 - 2005 - rx and ry values were reversed for I sections with horizontal web.
Ver. 2.2.04 2006/04/12
  • Design Parameters table were incomplete on the calcsheet page for SANS 10162 - 2005.
Ver. 2.2.03 2006/03/13
  • Maximum number of section properties increased from 200 to 500.
Ver. 2.2.02 2006/01/19
  • Maximum number of load combinations increased from 10 to 100.
Ver. 2.2.01 2006/01/18
  • Range check error fixed when "5 most critical" option and only some load cases were selected.
Ver. 2.2.00 2005/12/15
  • Maintenance release.
Ver. 2.1.04 2005/11/14
  • Design link from Frame now compatible with the new "stored output" option.
Ver. 2.1.03 2005/11/01
  • Position of the Settings dialog changed to support dual monitors.
Ver. 2.1.02 2005/05/11
  • Recompiled for compatibility with sections database.
Ver. 2.1.01 2005/03/29
  • Australian code (AS4100) added.
Ver. 2.1.00 2004/09/14
  • Maintenance release.
Ver. 2.0.02 2004/07/07
  • Maintenance release.
Ver. 2.0.01 1970/01/01
  • " 5 Most critical elements" (See Settings button) adjusted to allow for the selection of only some load cases.
Ver. 2.0.00 2003/05/08